Photovoltaic Cable // MG Wires // 1x4mm2, 0.6/1kV black H1Z2Z2-K-4mm2 BK, packaging 50m
Product code: ME6834
Shipping costs are not included in the price.
Shipping costs are not included in the price.
Shipping & Returns
Master Energy | Master Investment Sp. z o.o.
1. Right of Return (14 Days)
Individual consumers (B2C) have the right to withdraw from the contract and return purchased items within 14 calendar days from delivery without stating a reason.
2. How to submit a return or claim?
- 📧 E-mail: bok@masterenergy.eu
- 📞 Phone: +48 884 570 201
- 🏢 Registered Address: Master Investment Sp. z o.o., Rondo ONZ 1, 00-124 Warsaw, Poland (VAT ID: PL7010345632)
3. Complete terms and conditions
Detailed freight information, pallet shipping methods, and B2B commercial terms are available at our dedicated information page:
Payment methods
Ask about the product
Administratorem danych osobowych jest Master Investment sp. z o.o.. Przetwarzamy je w celu przesłania odpowiedzi na zapytanie. Więcej informacji dotyczących przetwarzania danych osobowych znajduje się w polityce prywatności.
Description
MG Wires H1Z2Z2-K 1x4.0 mm² is a photovoltaic cable designed for connections between photovoltaic panels and between panels and the inverter. The cable's construction ensures long-lasting operation in PV installations and resistance to atmospheric factors.
Manufacturer: MG WIRES Sp. z o.o. Sp.K. (Chybie). The manufacturer supplies cables compliant with the standard PN-EN 50618:2015-03, with declared resistance to UV and ozone, as well as meeting requirements for flame resistance and minimal release of aggressive smoke during combustion.
Electrical and operational parameters
- Rated voltage: 0.6/1 kV AC
- Operating voltage (DC): 1.5 kV DC according to EN 50618
- Insulation resistance: min. 580 MΩ·km at 20°C
- Maximum conductor operating temperature: +90°C (with short-term operation +120°C for up to 20000 h)
- Minimum ambient temperature for permanently installed cables: -40°C
- Minimum laying temperature: -25°C
- Test voltage (50 Hz): 4000 V
- Resistance: UV, ozone, atmospheric conditions; compliant with EN 50618
Mechanical parameters and dimensions
- Nominal cross-section of the conductor: 4.00 mm²
- Maximum permissible wire diameter in the conductor: 0.31 mm
- Nominal insulation wall thickness: 0.7 mm
- Nominal sheath wall thickness: 0.8 mm
- Maximum outer diameter of the cable: 6.6 mm
- Sheath colour: black
- Insulation and sheath: cross-linked halogen-free material
- Bending radius for fixed connection: min. 4 x Ø of the cable